titleFlexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort
authorsKabir Hamzah Muhammad, Lorena Garcia-Foncillas Macias, Soumya Snigdha Kundu, Emily Guilhem, Jon Cleary, Amal Saleh Nour, Yodit Abraham Yaynishet, Chinasa Kalaiwo, Peter Chibuta, Ugumba Kwikima, Udunna Anazodo, Jonathan Shapey, Tom Vercauteren
date2026-11-16
venuearXiv (preprint, not peer reviewed)
idarXiv:2611.21412
upvotes2 (Hugging Face Daily Papers, 2026-11-19)
linksabs pdf hf code
cite
abstractHigh-resolution brain MRI is important for neuroradiological assessment, yet routine clinical protocols often rely on fast, anisotropic 2D acquisitions, particularly in resource-constrained settings. These acquisitions may differ in orientation, alignment and anatomical coverage, resulting in partially overlapping image stacks. Existing learning-based super-resolution methods typically rely on single, under-constrained inputs or fixed multi-stack configurations with idealised acquisition geometry. We introduce MS-HVED, a sequence-agnostic framework for flexible multi-stack brain MRI super-resolution. Available axial, coronal and sagittal stacks are independently encoded into multi-scale Gaussian posteriors and fused using a field-of-view-aware Product-of-Gaussians formulation that limits contributions from unsupported regions. Physics-informed domain randomisation simulates heterogeneous clinical acquisition conditions, including obliqueness, partial coverage and imaging artefacts. MS-HVED achieved competitive or superior reconstruction fidelity across synthetic benchmarks and improved downstream tissue segmentation relative to low-resolution inputs. To assess generalisation beyond the training cohorts, we performed external clinical validation on 30 routine brain MRI examinations from a Nigerian cohort, representing an under-represented population in medical imaging research. These examinations formed the largest component of a blinded reader study involving 44 real cases and seven expert neuroradiologists. In the Nigerian cohort, MS-HVED was preferred over the supervised baseline for overall image quality in 187 of 210 paired assessments. Across all clinical cohorts, MS-HVED achieved higher overall-quality scores with all available inputs (5.93 vs. 4.49, p<.001), with the preference persisting when axial or coronal inputs were omitted (p<.001). Code at github.com/cai4cai/ms-hved

bibtex

@misc{muhammad2026flexible,
  title={Flexible Multi-Stack Super-Resolution of Clinical Brain MRI Using Hetero-Orientation Variational Encoding: Expert Reader Evaluation in a Nigerian Cohort},
  author={Kabir Hamzah Muhammad and Lorena Garcia-Foncillas Macias and Soumya Snigdha Kundu and Emily Guilhem and Jon Cleary and Amal Saleh Nour and Yodit Abraham Yaynishet and Chinasa Kalaiwo and Peter Chibuta and Ugumba Kwikima and Udunna Anazodo and Jonathan Shapey and Tom Vercauteren},
  year={2026},
  eprint={2611.21412},
  archivePrefix={arXiv},
  url={https://arxiv.org/abs/2611.21412}
}